Timstar - Science
Rasotherm Beakers, 100 mL
Borosilicate 3.3 glass beakers, graduated, with spout. Resistant to heat, temperature changes, and chemicals, to ISO 3819.
74.31 AED
Rasotherm Beakers, 250 mL
Borosilicate 3.3 glass beakers, graduated, with spout. Resistant to heat, temperature changes, and chemicals, to ISO 3819.
118.58 AED
Dicot Leaf Model
This detailed 3D rendering of a dicot leaf section, which is greatly magnified, is ideal for studying the structure and function of a dicot leaf. Structures featured include: cuticle, upper epidermis, hypodermis (collenchyma), pallisade parenchyma, spongy parenchyma, air spaces, chloroplasts, bundle sheath, sclerenchyma, xylem, phloem, lower epidermis, guard cells, and stomata. These key features are colored and numbered for comparison with the key card that is included. This model provides a visually and kinesthetically effective method for studying the structure and function of the various structures of a dicot leaf.
246.64 AED
Rasotherm Beakers, 50 mL
Borosilicate 3.3 glass beakers, graduated, with spout. Resistant to heat, temperature changes, and chemicals, to ISO 3819.
62.45 AED
Ohaus Pioneer PR124/E, 120 g x 0.0001 g
Offering accuracy and repeatability in essential weighing applications in education settings, PR balances deliver competitive performance at an economical price. Constructed with an ABS top housing, removable stainless-steel pan, removable glass draftshield with sliding top door, integrated weigh-below-hook, security bracket and calibration lock. Featuring RS232 connectivity for easy communication, and a backlit display and a simple interface for uncomplicated operation, the PR is perfectly designed for your classroom. •Applications - Basic Weighing, Parts Counting, Percent Weighing •Display - Backlit Liquid Crystal Display (LCD) •Operation - AC adapter (included) •Communication - RS232 (one port included) •Design Features - User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user-selectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator.
5810.18 AED
Ohaus Pioneer PR423/E, 420 g x 0.001 g
Offering accuracy and repeatability in essential weighing applications in education settings, PR balances deliver competitive performance at an economical price. Constructed with an ABS top housing, removable stainless-steel pan, removable glass draftshield with sliding top door, integrated weigh-below-hook, security bracket and calibration lock. Featuring RS232 connectivity for easy communication, and a backlit display and a simple interface for uncomplicated operation, the PR is perfectly designed for your classroom. •Applications - Basic Weighing, Parts Counting, Percent Weighing •Display - Backlit Liquid Crystal Display (LCD) •Operation - AC adapter (included) •Communication - RS232 (one port included) •Design Features - User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user-selectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator.
4632.33 AED
Ultra Microcentrifuge
A low-cost centrifuge, with fixed speed, quiet operation, and simple-to-use controls. The unit accelerates and brakes in seconds. The included rotors can be changed easily without tools. •Max Speed: 7000 rpm •Max. RFC: 2680 kg •Rotor Capacity: 0.2/0.5/1.5/2.0 mL x 8; 0.2 mL x 16 PCR strips or 0.2 mL x 2 PCR strips • Dimensions (D x W x H): 160 x 170 x 122 mm •Noise level: 45 dB (A) •Weight: 0.5 kg
1228.44 AED
UB-525 Automatic Wrist Blood Pressure Monitor
A simple to use, easy one button operation wrist blood pressure monitor, with lightweight, compact design, extra-large, easy to read LCD, and fast measurement. •60 readings memory recording for recording trending •Average reading function •World Health Organisation (WHO) Blood Pressure Classification Indicator •IHB Irregular Heart Beat indicator •Clinically Validated •5 year warranty (excluding batteries cuff) •Takes 2x AAA batteries
317.00 AED
Ohaus Pioneer PR2202/E, 2200 g x 0.01 g
Offering accuracy and repeatability in essential weighing applications in education settings, PR balances deliver competitive performance at an economical price. Constructed with an ABS top housing, removable stainless-steel pan, removable glass draftshield with sliding top door, integrated weigh-below-hook, security bracket and calibration lock. Featuring RS232 connectivity for easy communication, and a backlit display and a simple interface for uncomplicated operation, the PR is perfectly designed for your classroom. •Applications - Basic Weighing, Parts Counting, Percent Weighing •Display - Backlit Liquid Crystal Display (LCD) •Operation - AC adapter (included) •Communication - RS232 (one port included) •Design Features - User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user-selectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator.
4758.81 AED
Ohaus Pioneer PR4202/E, 4200 g x 0.01 g
Offering accuracy and repeatability in essential weighing applications in education settings, PR balances deliver competitive performance at an economical price. Constructed with an ABS top housing, removable stainless-steel pan, removable glass draftshield with sliding top door, integrated weigh-below-hook, security bracket and calibration lock. Featuring RS232 connectivity for easy communication, and a backlit display and a simple interface for uncomplicated operation, the PR is perfectly designed for your classroom. •Applications - Basic Weighing, Parts Counting, Percent Weighing •Display - Backlit Liquid Crystal Display (LCD) •Operation - AC adapter (included) •Communication - RS232 (one port included) •Design Features - User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user-selectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator.
5019.68 AED
Rasotherm Beakers, 600 mL
Borosilicate 3.3 glass beakers, graduated, with spout. Resistant to heat, temperature changes, and chemicals, to ISO 3819.
157.31 AED
Academy Conical Flask, Wide Mouth, 250 mL
Borosilicate glass, graduated, easy pour rim, wide-mouthed conical flask.
142.29 AED
Academy Heavy Duty Conical Flask, 100 mL
Borosilicate glass, graduated, narrow-mouthed, heavy duty conical flask.
117.39 AED
Rasotherm Conical Flask, Narrow Mouth, 250 mL
RASOTHERM® Erlenmeyer flasks, narrow neck. Borosilicate glass 3.3 ISO 1773. With graduation. Resistant to heat, temperature changes and chemicals.
126.48 AED
Academy Conical Flask, Wide Mouth, 100 mL
Borosilicate glass, graduated, easy pour rim, wide-mouthed conical flask.
102.77 AED
Filter Funnel, Glass, 55 mm
Borosilicate glass, plain pattern, angled tip, short stem, filter funnel.
14.00 AED
Academy Heavy Duty Conical Flask, 250 mL
Borosilicate glass, graduated, narrow-mouthed, heavy duty conical flask.
77.86 AED
Filter Funnel, Glass, 45 mm
Borosilicate glass, plain pattern, angled tip, short stem, filter funnel.
14.00 AED
Rasotherm Media Bottle, 250 mL
•Borosilicate 3.3 •ISO 4796-1 •Graduated •Polypropylene screw cap and pouring ring •Resistant to heat, temperature changes, and chemicals •Supplied in packs of 11
182.61 AED
Rasotherm Media Bottle, 500 mL
•Borosilicate 3.3 •ISO 4796-1 •Graduated •Polypropylene screw cap and pouring ring •Resistant to heat, temperature changes, and chemicals •Supplied in packs of 12
223.71 AED
Rasotherm Beakers, 1000 mL
Borosilicate 3.3 glass beakers, graduated, with spout. Resistant to heat, temperature changes, and chemicals, to ISO 3819.
344.66 AED
Rasotherm Media Bottle, 100 mL
•Borosilicate 3.3 •ISO 4796-1 •Graduated •Polypropylene screw cap and pouring ring •Resistant to heat, temperature changes, and chemicals •Supplied in packs of 10
156.52 AED
Rasotherm Conical Flask, Narrow Mouth, 50 mL
RASOTHERM® Erlenmeyer flasks, narrow neck. Borosilicate glass 3.3 ISO 1773. With graduation. Resistant to heat, temperature changes and chemicals.
148.80 AED
Rasotherm Conical Flask, Narrow Mouth, 100 mL
RASOTHERM® Erlenmeyer flasks, narrow neck. Borosilicate glass 3.3 ISO 1773. With graduation. Resistant to heat, temperature changes and chemicals.
112.25 AED
Rasotherm Media Bottle, 1 litre
•Borosilicate 3.3 •ISO 4796-1 •Graduated •Polyproplyene screw cap and pouring ring •Resistant to heat, temperature changes, and chemicals •Supplied in packs of 13
365.21 AED
Ohaus CR Series, CR621, 620 g x 0.1 g
This Compass CR balance provides basic weighing functionality and competitive performance at an economical price. Features such as a slim, stackable design, and an enlarged weighing platform, make the CR series perfect for a variety of portable weighing applications. •Display - Liquid Crystal Display (LCD) •Operation - 3 AA batteries (included) or AC adapter (not included) •Construction - ABS housing and pan, transportation lock, slip-resistant feet •Design Features - Stability indicator, mechanical and software overload/underload protection, auto shut-off.
276.68 AED
Replacement Caps for McCartney Bottles
Aluminium screw cap and rubber liner for McCartney bottles.
250.59 AED
Ohaus CR Series, CR221, 220 g x 0.1 g
This Compass CR balance provides basic weighing functionality and competitive performance at an economical price. Features such as a slim, stackable design, and an enlarged weighing platform, make the CR series perfect for a variety of portable weighing applications. •Display - Liquid Crystal Display (LCD) •Operation - 3 AA batteries (included) or AC adapter (not included) •Construction - ABS housing and pan, transportation lock, slip-resistant feet •Design Features - Stability indicator, mechanical and software overload/underload protection, auto shut-off.
245.06 AED
Dropping Bottles, Timstar, Clear, 30 mL
Glass with vinyl teat, plastic interchangeable stopper and glass pipette. Supplied in packs of 10.
242.29 AED
Rekrow RK4601 Portable Gas Burner, Each
Recommended by CLEAPSS' guide GL240, a high-quality burner with refillable gas tank and thumb-operated electric ignition. It provides stable, controllable flame. The housing stays cool enough to touch even after sustained use. • Heavy base design for stability • Easy to refill • Electric instant ignition system • Built-in safety pressure release valve • 35 minutes large flame on full tank • 70 minutes small flame on full tank • Can be refilled with GA130510 • Rekrow model RK4601 • Flame temperature up to 1,250 °C • Output 0.75 kW • 30 g tank capacity • Consumption: 56 g/hour • Base diameter: 79 mm • Width: 127 mm • Height: 75 mm • Weight: 410 g (without fuel) • CE marked
313.83 AED
Rekrow RK4601 Portable Gas Burner, Pack 10
Recommended by CLEAPSS' guide GL240, a high-quality burner with refillable gas tank and thumb-operated electric ignition. It provides stable, controllable flame. The housing stays cool enough to touch even after sustained use. • Heavy base design for stability • Easy to refill • Electric instant ignition system • Built-in safety pressure release valve • 35 minutes large flame on full tank • 70 minutes small flame on full tank • Can be refilled with GA130510 • Rekrow model RK4601 • Flame temperature up to 1,250 °C • Output 0.75 kW • 30 g tank capacity • Consumption: 56 g/hour • Base diameter: 79 mm • Width: 127 mm • Height: 75 mm • Weight: 410 g (without fuel) • CE marked
2780.98 AED
Rekrow RK4102 Portable Lab Burner, Each
Recommended by CLEAPSS' guide GL240, a high-quality portable laboratory burner, with refillable gas tank and thumb-operated electric ignition. It provides an adjustable flame, similar to a Bunsen burner. The tank stays cool enough to touch even after sustained use. • Heavy base design for stability • Easy to refill • Electric instant ignition system • Built-in safety pressure release valve • 35 minutes large flame on full tank • 80 minutes small flame on full tank • Can be refilled with GA130510 • Flame temperature up to 1,250 °C • 30 g tank capacity • Width: 115 mm • Height: 96 mm • Weight: 430 g (without fuel)
357.31 AED
Rekrow RK4102 Portable Lab Burner, Pack 10
Recommended by CLEAPSS' guide GL240, a high-quality portable laboratory burner, with refillable gas tank and thumb-operated electric ignition. It provides an adjustable flame, similar to a Bunsen burner. The tank stays cool enough to touch even after sustained use. • Heavy base design for stability • Easy to refill • Electric instant ignition system • Built-in safety pressure release valve • 35 minutes large flame on full tank • 80 minutes small flame on full tank • Can be refilled with GA130510 • Flame temperature up to 1,250 °C • 30 g tank capacity • Width: 115 mm • Height: 96 mm • Weight: 430 g (without fuel)
3154.10 AED
SATZ School Power Station 1.5A
This safe, reliable power supply is lightweight and robust. It features short-circuit protection, overload protection with automatic reset, and thermal cut-out. Regulated DC with a simple rotating switch to select the voltage, as well as an on/off switch. Output is via colour-coded terminal sockets. The selectable output voltage wheel ranges from 3 V, 4.5 V, 6 V, 7.5 V, 9 V and 12 V. Conforms to CE:EN61010-2010
296.44 AED
SATZ School Power Station 3A
This safe, reliable power supply is lightweight and robust. It features short-circuit protection, overload protection with automatic reset, and thermal cut-out. Regulated DC with a simple rotating switch to select the voltage, as well as an on/off switch. Output is via colour-coded terminal sockets. The selectable output voltage wheel ranges from 3 V, 4.5 V, 6 V, 7.5 V, 9 V and 12 V. Conforms to CE:EN61010-2010
397.62 AED
Lens & Mirror Holder
Metal spring clip holder with grooves to hold 50 mm round lenses or mirrors, mounted on base with slot cut out to accommodate metre or half metre rule.
31.22 AED
Function Generator, Student Model
A high-quality simple-to-use student signal generator with a range of applications. Operated with just three buttons: Waveform, Frequency and Amplitude. There is a single output, provided with 4 mm safety sockets. The output can easily drive a speaker or vibrator with ample amplitude for resonance and diffraction experiments. The frequency range extends well beyond the audible range. The lowest frequencies are suitable for ""slow motion AC"" experiments. Unique frequency control The frequency is set with a speed-sensitive button. If you turn slowly, the last digit of the display is set. Turning faster, the response accelerates smoothly. The generator covers the six decades from 0.05 Hz to 50.00 kHz in a single range. The frequency is stable within 0.005 % Three waveforms The generator provides sine, triangle, or square wave signals. Distortion of the sine wave is less than 0.25 % in the audible range (20 Hz - 20 kHz) and remains below 1 % throughout the frequency range (0.05 Hz - 50 kHz). Built-in power amplifier The signal amplitude is continuously adjustable from 0 V to a peak voltage of 7.5 V (15 V p-p; 5.3 V RMS). More than 1 A peak current can be supplied. The output is overload protected. Supplied with 12 V power adapter.
2213.40 AED
High Tension (HT) Power Supply
Voltages of 0 to 30 V DC and 0 to 300 V DC at up to 60 mA. Outputs are fully floating to provide negative voltages if required and are taken from pairs of colour-coded 4 mm sockets on the front panel. Each output has a continuously variable voltage control, with electronic current limiting circuitry. An indication of the output voltage is given by a graduated scale on each voltage control. A pair of 4 mm sockets on the front panel provide 6.3 V AC at up to 2 A for filament heating. An illuminated on/off switch is mounted on the rear panel adjacent to a fused appliance inlet. Housed in a robust metal case with a durable powder coated finish. •DC Output Voltage Range No1: 0 to 30 V DC •DC Output Voltage Range No2: 0 to 300 V DC •Maximum DC Output Current: 60 mA (both ranges) •AC Output Voltage: 6.3 V AC •Maximum AC Output Current: 2 A
1572.70 AED
Battery Replacement PSU
A low-cost alternative to dry cell batteries. Housed in a robust ABS plastic case, this power supply is ideally suited as a replacement in applications where batteries are normally used. Smoothed and regulated DC is available over those ranges selected by rotary switch. Output is via 4 mm red and black sockets. The DC output voltage available are 1.5, 3, 4.5 and 6 V DC at a maximum current of 1 A.
785.10 AED
Varivolt Power Supply
Continuously variable 0 to 20 V AC and full-wave rectified DC at maximum 6 A continuously or 8 A for short periods. Resettable thermal cut-out. Outputs from two pairs of colour-coded 4 mm sockets. Output voltage is indicated by means of a calibrated scale. An illuminated on/off switch is mounted on the rear panel adjacent to a fused IEC mains inlet. Enclosed in a robust metal case with a durable powder coated finish. •AC Output Voltage Range: 0 to 20 V AC •Maximum AC Output Current: 6 A (8 A short period of time) •DC Output Voltage Range: 0 to 20 V DC •Maximum DC Output Current: 6 A (8 A short period of time)
1573.10 AED
Lo-Volt Power Supply
This unit provides voltages of 2, 4, 6, 9, 12 or 14 V AC or full-wave rectified DC at 4 A continuously, or up to 5 A for periods of 1 hour. Voltages are selected by means of a rotating switch on the front panel. In any incidence of overload, including direct short, a current sensing circuit breaker mounted on the front panel will operate and disconnect the output voltage. Outputs are taken from colour coded 4 mm sockets mounted on the front panel. An illuminated on/off switch is mounted on the rear panel adjacent to a fused appliance inlet. Housed in a robust metal case with a durable powder coated finish. Supplied with mains lead and instructions. •AC Output Voltage Range: 2, 4, 6, 9, 12 and 14 V AC •Maximum AC Output Current: 4 A (5 A up to 1 hour) •DC Output Voltage Range: 2, 4, 6, 9, 12 and 14 V DC •Maximum DC Output Current: 4 A (5 A up to 1 hour)
1019.75 AED
5 kV EHT Power Supply
Continuously variable output from 100 V to 5 kV DC. Output voltage is indicated on a 14 mm 2-digit LED display. The EHT circuits are fully floating so that for certain applications the positive or negative terminal may be safely connected to earth. The EHT outputs are taken from 4 mm shrouded sockets and provide 100 V to 5 kV DC at up to a maximum of 3 mA or current limited to 60 µA. A centre tapped socket is provided to give ±2.5 kV DC output. An additional pair of 4mm shrouded sockets at 19mm spacing are provided giving 6.3 V AC at 2 A for filament supplies. There is also a separate earthing terminal. An illuminated on/off switch is mounted on the rear panel adjacent to a fused IEC mains inlet. Enclosed in a robust metal case with a durable powder coated finish. Supplied with instructions and detachable mains lead. •DC Output Voltage Range: 100 V to 5 kV DC •Maximum DC Output Current: 3 mA •Maximum DC Limited Current: 60 µA •AC Output Voltage: 6.3 V AC •Maximum AC Current: 2 A Accessories •5 kV Lead Red: EL91360 •5 kV Lead Black: EL91362
2628.41 AED
Signal Generator & Amplifier
This signal generator and amplifier provides sine, square or triangular waveforms. Frequency selection is by a switched range and continuously variable fine adjustment control. The frequency is displayed on an LED display. All connections are via pairs of labelled 4 mm sockets with one of each pair connected to earth. An illuminated on/off switch is mounted on the rear panel adjacent to a fused IEC mains inlet. Enclosed in a robust metal case with a durable powder coated finish. Signal Generator Mode: •Waveforms - Sine, Square & Triangular, sinewave distortion 1% on all ranges, square wave rise time 1 µs approx. •Frequency Range - 0.1 Hz to 100 kHz in six ranges, accuracy ±5% on all ranges •Voltage Output - 0 to 10 V (peak to peak), continuously variable across all ranges & waveforms •4 Ω Output - Power output of 4 W over entire frequency & waveforms, will drive loudspeaker or other suitable devices •600Ω Output - Provides attenuation settings: x 1, x 0.1 & x 0.01, all ±5% Amplifier Mode: •Performance - Voltage gain 0 to 100, Input impedance 1 MΩ, Max. input 200 mV (pk to pk), Output spec. same as above •Frequency Response - Frequency response 1 Hz to 100 kHz (-3 dB bandwidth)
2331.98 AED
Signal Generator
Sine and square wave generator. Frequency range 5 Hz to 50 kHz in four switched ranges plus a fine control. Accuracy typically ±10%. The output amplitude is continuously variable from zero to maximum 8 V peak to peak with maximum output power 1 W into 8 ohms. The output is taken from two 4 mm sockets mounted on the front panel. An illuminated on/off switch is mounted on the rear panel adjacent to a fused IEC mains inlet. Enclosed in a robust metal case with a durable powder coated finish.
1185.75 AED
Irwin Powerbase S8
The Powerbase S8 offers 0 to 12 V at 8 A via a safe relay switching system that provides voltages in 1 V steps. AC and DC voltages are available simultaneously in any combination up to a combined output of 8 A. The output is safely protected by a thermal cut out switch on the front panel with an output limiter which allows the user to preset the maximum voltage available. 0 to 12 V AC/DC in 1 V steps 8 A combined simultaneous output lockable via an Allen key mechanism. • Maximum output 0-12 V DC & 0-12 V AC • Current 8 A • Supplied with Allen key to lock minimum or maximum output • Voltage selector type - Relay switched • Output type - Smooth non-regulated • Push button trip reset • Mains input 230/240 V AC, 50 Hz • Supplied with mains plug and lead + Allen key • Manufactured in the UK
1470.33 AED
Irwin Powerbase V8
The Powerbase V8 comes with a high-power rotary transformer and a high specification toroid transformer. The unit supplies 0-20 V smoothed DC and 0-16 V AC at 8 A. The output is continuously variable and protected by a panel mounted thermal cut out. An output limiter is fitted which allows the user to preset the maximum voltage available. •A heavy-duty power supply for powering laboratory experiments •Heavy duty variable transformer and high-power toroid transformer •Continuously variable output of 0 to 16 V AC and 0 to 20 V DC, capacitor smoothed •Output current 8 A. Output voltages are rated at 8 A load so higher voltages are available at less output current. •Manufactured in the UK with 5 years warranty •AC and DC outputs may be used simultaneously up to rated current. •Colour coded 4 mm sockets. •Maximum voltage limiter operated by Allen key •Push button cut-out to protect against overload and short circuit conditions •Mains Input 230 V, 50 Hz •Fusing: 5 A mains plug fuse
1462.43 AED
Irwin Case Repair Kit
This repair kit for Irwin power supplies allows damaged plastic cases to be replaced quite easily. The kit comprises brand new plastic case in original Irwin blue, gloss black or crystal clear, three ""mushrooms"", which fit on the back of the case and act as cable tidy, new cable clamp and complete fitting instructions. In case of difficulties removing the old cable clamp and cable, specially designed tool to make the job easier is also available.
284.58 AED
